You are here: Home / Products / Viscometer / ZGNTV-T1 Touch Screen Viscometer, Fluid Meter for Polymer Solutions,Cosmetics,Milk Products etc

loading

ZGNTV-T1 Touch Screen Viscometer, Fluid Meter for Polymer Solutions,Cosmetics,Milk Products etc

The viscosity temperature control integrated machine integrates viscosity measurement and precise temperature control. Breaking through the existing market of using a constant temperature water bath, viscosity measuring instrument, and small sample adapter to form a split machine.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The viscosity temperature control integrated machine integrates viscosity measurement and precise temperature control. Breaking through the existing market of using a constant temperature water bath, viscosity measuring instrument, and small sample adapter to form a split machine. 


The all-in-one viscosity measurement system consists of a 7-inch large touch screen host, a columniform sample sleeve of a small sample adapter (SSR), a 5C4 rotor, and a temperature controller; 


The amount of sample required for testing is only 2 to 16m, and the cylindrical geometric structure of SC4 rotor can provide very accurate viscosity measurement. 


  • Electric control for lifting and precise positioning. The small sample sleeve is easy to install and unload, which brings convenience to cleaning work. The small sample cylinder is closely connected to the temperature controller, which can accurately measure the sample temperature. 

  • The stirring action of the rotor, coupled with the small sample size, can minimize the unevenness of the sample temperature and greatly shorten the constant temperature time; 

  • The viscosity measurement system comes with password protection for temperature and viscosity correction coefficients, allowing users to correct temperature and viscosity correction coefficients on their own with reliable and accurate data; 

  • Support infinitely variable speed viscosity measurement, inputting any speed directly reflects the full range of each rotor, making it convenient for users to select testing conditions: support external USB data storage; 

  • Choose from three storage methods: single point, continuous, and timed,

  • Accurate temperature control is very helpful for testing the performance changes of your sample and predicting product behavior. Controlling the temperature during viscosity measurement helps ensure the accuracy of experimental results. 


Due to the use of semiconductor and built-in automatic optimization temperature program control components in the temperature controller, the temperature control accuracy is +0.1. The temperature control is controlled by the ZGNTV-T1 integrated machine, and can also be controlled through SNB software. Has excellent operational performance and flexibility.



Features:

1.7-inch intelligent touch operation, including integrated display of dynamic viscosity value, kinematic viscosity value, viscosity temperature curve and other information.

2.electric automatic lifting system, viscosity measurement and temperature control part - integrated design, positioning correct.

3.temperature control can be set directly on the screen, temperature can be set at a single touch.

4.external USB data storage is supported, the kinds of storage methods for your choice: single point, continuous, and timed.

5.password protection of temperature and viscosity correction coefficients, allowing users to self correct temperature and viscosity correction coefficients with reliable and accurate information.


Main Technical Parameters:

Model

ZGNTV-T1

Test range/mPa.s

L measuring

range :50000-330000

R measuring

range: 50-3.3M

HA measuring

range: 100-6.6M

HB measuring

range: 600-26.4M

Temperature control   range

-1℃--150℃

Rotor rotational speed (rpm)

0.3-100

Rotor number

Four kinds of standard configuration: SC4-21、27、28、29.

Measurement Accuracy

Optional: SC4-14, 15, 16, 18, 25, 31, 34

Repeatability

±1.0%(full range) ±0.2%(full range)

Supply power

AC100-240V 50Hz/60Hz, output DC12V1.5A




Optional Accessories:

SNB data acquisition and plotting software, standard oil.



Applications:

Suitable for detecting low, medium, and high viscosity fluids.





Previous: 
Next: 

Related Products

Testing refractive index nD, average dispersion (nF nC) of liquids or solids and the mass fraction (known as Brix) of dry solids in sugar solution.
Application for detection and analysis in sugar, pharmaceutical, beverage, petroleum, food, chemical industry production, scientific researchand teaching departments.
0
0
1: Support network printing and data statistical retrieval;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1.Contains 2-channel liquid adding module, standard 16 stations, optional 20/34/40 station turntable auto sampler.
2.Can drive multiple liquid adding module units, burettes and pipelines should be acid, alkali and corrosion resistant.
3.Imported corrosion-resistant polytetrafluoroethylene rotary valve, PTFE corrosion-resistant burette, high-power stirring table, coil for magnetic stirring.
4.High-precision closed-loop control to ensure accurate titration.
0
0
1: Improve precision and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: The whole machine has passed the TART and CE certification;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Meet 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020, cGMP/GLP requirements and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
Adopting visual aiming and manual measurement methods, it is easy to use.
0
0
Adopting photoelectric detection and automatic servo mechanism control, digital display reading, capable of measuring dark samples; It can also measure sugar content and is equipped with an RS232 interface, which can transmit data to a PC.
0
0
1.The control unit adopts a 16 bit microprocessor chip, which makes the computer faster and has good real-time performance.
2.Digital temperature control regulation has been achieved, allowing for arbitrary setting of starting temperature and selection of different linear heating rates.
3.Enhanced anti-interference capability through digital filtering technology.
4.It can automatically record the initial and final melting temperatures.
0
0
1: Test mode: melting point, boiling point, sliding point;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Comply with 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1.4-channel fluid-addition module, standard 40 stations.
2.Four liquid adding module units, burettes and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
1.4-channel fluid-addition module, standard 16 stations, optional 20/34/40 stations rotary type automatic sampler can be added.
2.Four liquid adding module units, burettes and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
1.Imported solenoid valve, PTFE corrosion resistance burette, high-power mixing table, using the coil to achieve magnetic mixing;
2.High-precision closed-loop control, ensuring accurate titration;
3.High-precision titration buret is accurate to 0.003mm;
4.The whole pipeline is fully sealed design, fast and convenient replacement;
0
0
1.Imported solenoid valve, PTFE corrosion resistance burette, high-power mixing table, using the coil to achieve magnetic mixing;
2.High-precision closed-loop control, ensuring accurate titration;
3.High-precision titration buret is accurate to 0.003mm;
4.The whole pipeline is fully sealed design, fast and convenient replacement;
0
0
1.2-channel fluid-addition module, standard 16 stations, optional 20/34/40 stations rotary type automatic sampler can be added.
2.Two liquid adding module units, burettes and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
1.2-channel fluid-addition module. Optional 16/20/34/40 stations rotary type automatic sampler can be added.
2.Two liquid adding module units, burettes and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
1.Single fluid-addition module. Optional 16/20/34/40 stations rotary type automatic sampler can be added.
2.The driven liquid adding module unit, burette and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
1.4-channel fluid-addition module, standard 34 stations.
2.Four liquid adding module units, burettes and pipelines all can be acid-proof, alkali-proof and corrosion resistance.
3.Imported corrosion-resistant PTFE rotating valve, PTFE corrosion-resistant burette, high-power mixing table, using the coil to achieve magnetic mixing.
4.High-precision closed-loop control, ensuring accurate titrating.
0
0
Coated dissolution cup, automatic center positioning.
It can store at least 200 experimental methods. The software has the functions of permission management and audit tracking, and can store at least 100 preset login accounts and passwords, and operation authority hierarchical management.
0
0
To determine the drop points and softening points of noncrystallographic polymer compounds, to determine their concentration density, polymerization degree, heat resistance and other physical and chemical characteristics;
0
0
1. Coated dissolution cup, automatic center positioning.
2. At least storing 300 experimental methods, the software has authority management and audit tracking functions.
3. It can store at least 300 preset login accounts and passwords, operating authority grading management.
4. At least 3 authority levels can be assigned; the details of each authority level can be customized by the customer based on their own risk assessment.
0
0
The GV20K Karl Fischer Coulomb moisture analyzer adopts a 5.7-inch capacitor high-definition color touch screen, which is effortless and easy to operate like a mobile phone. The operation interface is simple and intuitive, and the navigation based operation mode reduces learning costs and makes it faster to get started.
0
0
The pH meter is a commonly used instrument, mainly used to accurately measure the pH value of liquids. It is widely used in water environment testing, industry, electric power, agriculture, medicine, food, scientific research and environmental protection and other fields.
0
0
The viscosity temperature control integrated machine integrates viscosity measurement and precise temperature control. Breaking through the existing market of using a constant temperature water bath, viscosity measuring instrument, and small sample adapter to form a split machine.
0
0
1. Double temperature probe to ensure the high repeatability of the sample temperature measurement.
2. The digital gas mass flowmeter automatically switches two gas flow rates, with fast switching speed and short stability time.
3. Standard sample, convenient for customers to correct the temperature coefficient.
4. The instrument comes with an automatic calibration function.
0
0
Dual beam optical path can effectively suppress the drift of circuit optical path, suitable for long-term testing
Automatic wavelength calibration, automatic dark current and blank correction, automatic switching of light source and filter
Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory parts required for testing
0
0
The GR series fully automatic refractometer is equipped with high-performance linear CCD photosensitive components, and is equipped with a semiconductor Peltier super temperature control system through high-speed and high-precision signal acquisition and analysis processing technology.
0
0
GR15 visual discrimination reading scale. It can efficiently and accurately measure the refractive index (nD) of various liquids such as transparent, semi transparent, dark, and viscous, as well as the mass fraction (Brix) of sugar solutions.
0
0

Request A Free Quote

We are always ready to assist you with your inquiries. You can contact us via email, and we will make every effort to help resolve your issues and meet your needs.
Contact Us
Shanghai Zhuoguang Instrument Technology Co., Ltd. focuses on the scientific instrument industry, manufacturing high-quality instruments and providing perfect services.

Quick Links

Contact Us
 +86 18964419749
 +86 18964419749
 +86-21-59501820
 Room 308B, Building1, Tongxing Creative Industrial Park, Caoan Road 4260, Jiading District, Shanghai, 201804, China.
Leave a Message
Contact Us
Copyright © 2025 Shanghai Zhuoguang Instrument Technology Co., Ltd.  All Rights Reserved. Sitemap | Privacy Policy